Intellisite’s unique Pump Off Controller (POC) data display enables the operator to manage and control single units to entire fields of Rod Pump Controllers. IntellisiteSM offers an industry leading web-based remote monitoring service that collects critical pumping unit data and converts it into information to help you efficiently manage and optimize your well sites. The POC Monitoring Service delivers field records of over 122 registers including surface and downhole cards on a daily basis.
POC Features & Benefits:
POC Monitoring Services:
IntellisiteSM offers four different service options that meet the specific needs of your site:
IntellisiteSM Right Smart™ Technical Specifications:
The Right Smart™ 1200 solution integrates the unique technologies of IntellisiteSM with your existing pumping units to deliver comprehensive and accurate measurement information through our powerful, web-based reporting platform. Right Smart™ collects key production data from your field equipment, builds a history, and then encodes and compresses it for efficient transfer via the best path: radio, telephone or satellite telemetry. The production data is transported in high security to the world-class Implicit™ Monitoring Solutions Data Center, where it is converted into decision-critical information that is delivered by our web-based reporting platform. The Right Smart™ kit is compactly designed and uses either a RS232 input port or a RS485 input port if required.
| Features and Functionality of Right Smart™ 1200 Kit | ||
| Analog Inputs | (4) 0-5d or 1-5 Vdc | |
| Discreete / Pulse Input | (2) Dry Contact Closures | |
| Discrete Output | (1) Open Collector, 15 Vdc @ 100 ma Max | |
| Protection | Transient protection is provided in-circuit | |
| Communications | Iridium Satellite; Orbcom Satellite | |
| Optional Battery | 12Vdc, 15 AH | |
| Optional Solar Panel | 10 watts to 20 watts | |
| Local Readout | Optional LCD 4 x 20 characters; temperature compensated | |
| Dimensions | 5.5" L x 2.5" H x 1.75" W (14cm L x 6.4cm L x 4.5cm H) | |
| Operating Temperature | -40° to + 140° F not including LCD readout | |
| Operating Humidity | 0 - 95% non-condensing | |
| Meter Interfaces | Total Flow 6413, XF6413, and uFlow 6213 using modbus protocol Fisher FlowBoss 103 and 503 using ROC protocol NuFlo 1140 and 1150 using modbus protocol Eagle Research using modbus protocol | |
| Alarms | Low DP, high DP, low AP, high DP, low flow rate, high flow rate, back flow, low flowing temperature, high flowing temperature, low battery voltage, high battery voltage, contact closures for compressors | |